Reference Guide
4-97
System Configuration and Operation WAN Card Redundancy
Figure 4-65. Typical Cross-Connect System with WAN Card Redundancy
Figure 4-66 shows a WAN Card Main Screen for the card in slot W1 with port 1-1 selected.
To force a switch, press “
w
” (
sWitch
command), then press "
y
" to complete the switch. The
traffic on the WAN card in slot W1 will be switched to the WAN-R card in slot W4. The Main
System Screen (see Figure 4-66) now shows both ports of the card in slot W4 as active port
(Status =
aa
) and the ports on the card in slot W1 as redundant (Status =
rr
).
Node_1 | | 12-31-99 14:33
Slot Installed Status
C1 CPU XCON
C2
P1/U1 E&M 4Wx8ER ssssssss
P2/U2 E&M 4Wx8ER ssssssss
P3/U3 FXS 2Wx8-9 ssssssss
P4/U4 SRU 232x10 ssssssssss
W1/U5 CSU+CSU aa
W2/U6 CSU+CSU aa
W3/U7 CSU+CSU aa
W4/U8 CSU+CSU rr
IF INTF+modem
S1 PS1
S2 PS2
S3 Ringer
Alarms | Config | Del | accepT | Xcon | sYs | Logout | Oos | cpusWtch